Low Prices: Measure fill levels without putting a strain on the budget
Universal Usage: It’s usable even in the deepest basement, thanks to NB-LoT module;
Metering: it’s characterized by the maximum precision thanks to a infra-based method;
Easy to install: For optimal transmission, the tracker should be installed outside an object with a clear view to the sky. The view must not be obstructed by metal or carbon fiber surfaces. Mounting in a closed metal enclosure can completely block radio signals, and transmitting and receiving them is no longer possible.
Inside Encapsulated electronics for robust applications with a battery service life of five years on average
Communication Interface
REST, MQTT-SN
Device Size
43.48 x 85.89 x 68.00mm
Weight
<200g
IP Class
IP65
Operating Temperature
Min -20°C Max 60°C (with Chip-SIM)
Storage Temperature
Optimum 20-30°C (with Chip-SIM)
Operating Humidity
5% to 95% (non-condensing)
Storage Humidity
5% to 70% (non-condensing)
Number of SIM Slots
1x Chip-SIM
Power consumption
Quiescent current < 15uA NB-IOT Transmission < 400mA NB-IOT Receiving current < 100mA Data acquisition current < 600mA Average power consumption 0.65mAh/day Typical battery lifetime > 5 years@1.5 transmissions/day and 2 FOTA updates
Operational Voltage
2.5- 3.0 Volt
DC
AC
Internal Battery
4800mAh@3V (Li-MnO2), 1,6g Lithium
Yes
No
LTE NB-IoT
Cat NB2: B1/B2/B3/B4/B5/B8/B12/B13/B17/ B18/B19/B20/B25/B28/B66/B70/B85
Antenna designed for
B8@900MHz B20@800MHz Other bands can be supported upon request
Accelerometer
3-Axis Accelerometer
Temperature Sensor
Integrated Temperature Sensor
Distance Sensor
Time of Flight (ToF) 5cm-160cm (Version A)
Distance Sensor
Time of Flight (ToF) 5cm-400cm (Version B)
EN301489-1 V2.2.3 EN301489-52 V1.2.1
EMC
EN301908-1/-13
Conducted RF
EN62368
Safety
EN62311
SAR
2011/65/EU
RoHS
2012/19/EU
WEEE WEEE-Reg.-Nr.: DE16378411
Other Certificates
UL1642
Only for batteries
UN38.3
Transportation
2006/66 EC 2013/56/EU
Battery Directive
EN 60068-2-5
UV resistance
IEC60086-4:2014
Safety of lithium batteries
There are two types of Level Meter equipped with different time-of-flight (TOF) sensors. The types are identified by the first serial number letter (SN prefix):
The Level Meter must be installed in a location free from significant mechanical stresses, such as shocks, impacts, vibrations, bending, or torsional forces.
To ensure optimal cellular transmission, mount the device externally with a clear line of sight. Avoid blocking the view with metal or carbon fiber surfaces, as these can interfere with signals. Installation inside a closed metal container may fully block transmission and reception.
Due to the dead weight of the Level Meter, mounting using tape is not recommended.
UN Classification
UN 3091 Lithium metal batteries in equipment, 9
Relaxation of requirement
SV 188 / SP 188 may be applicable since the batteries contain < 2g lithium.
Packaging
The batteries are protected by the device housing. As a result, there are no special requirements.
Labeling
Labeled with label UN 3091 if more than 2 packing units with 2 Level Meters units each are sent. No label is required when sending a maximum of 2 packages with 2 Level Meters units each.
Labeling for ocean freight Container
Not required
Documentation
No documentation is required.
Miscellaneous
Employees involved must be trained according to their tasks and responsibilities.
UN Classification
Road: UN 3091 Lithium metal batteries in equipment, 9 (E) Rail: UN 3091 Lithium metal batteries in equipment, 9
Relaxation of requirement
Exception according to 1.1.3.7 b) ADR/RID IMDG Code SP 188. SP 188 applies since the lithium content < 2 g
Packaging
The batteries are protected by the device housing. As a result, there are no special requirements.
Labeling
Labeled with label UN 3091 if more than 2 packing units with 2 Level Meters units each are sent. No label is required when sending a maximum of 2 packages with 2 Level Meters units each.
Labeling for ocean freight Container
Not required
Documentation
No documentation is required.
Miscellaneous
Employees involved must be trained according to their tasks and responsibilities.
UN Classification
PAX/CAO air freight: UN 3091 Lithium metal batteries in equipment, 9
Relaxation of requirement
Exception according to 1.1.3.7 b) ADR/RID IMDG Code SP 188. SP 188 applies since the lithium content < 2 g
Packaging
The batteries are protected by the device housing. As a result, there are no special requirements The packaging complies with PI 970, Section II.
Labeling
Labeled with label UN 3091 if more than 2 packing units with 2 Level Meters units each are sent. No label is required when sending a maximum of 2 packages with 2 Level Meters units each.
Labeling for ocean freight Container
Not required
Documentation
No documentation is required.
Miscellaneous
The product complies with UN HANDBOOK OF TESTING AND CRITERIA - PART III, SECTION 38.3 - LITHIUM METAL AND LITHIUM ION BATTERIES. Employees involved must be trained according to their tasks and responsibilities.
Before first use, low-cost trackers must be awakened from sleep mode to start measurements and send transmissions. Follow these steps:
Remove the cover from the lens
Shake the device several times in the ToF direction.
Check the LED on the back of the device.
If Step 2 was successfully completed, the LED on the back should light up (mode "Always On").
If the LED does not light up, repeat Step 2.
Verify whether the registration was successful:
Observe the LED:
+ The LED will blink rapidly for 3 seconds and then turn off, indicating that the device has been successfully activated.
+ This process can take up to 3 minutes. After successful activation, the LED will not light up even if Step 2 is repeated.
Observe the LED:
+ If the LED turns off without blinking, the activation procedure has failed.
+ Possible causes:
a. An invalid network.
b. An issue with Deutsche Telekom's gIoT Cloud platform.
The level meter regularly reports the current fill level of the container.
Fill level thresholds are set according to specific requirements.
When a threshold is reached, an alarm is triggered to ensure the container is replaced or emptied as quickly as possible.
Thanks to the process of optimization, the collectionis not performed at set time intervals, but the Leve Meter automatically determines the fill level
Optimization of container runs;
Reduction of manual administrative overhead;
Prevention of collections too early or too late.
Process optimizations mean substantial reduction of CO2 emissions
Connection with the company’s NB-IoT network IoT cloud services from the certified Cloud
Low costs and fixed price make for calculable costs
No investment required in own wireless infrastructure
Process optimizations mean fuel and manpower savings
The battery cannot be charged: the device includes two lithium batteries belonging to one battery package.
Improperly handling the battery can cause a fire. Do not damage or cut the device.
Use the device only if it can be ensured that no personal injury or property damage can occur due to the installation type.
As the manufacturer, Virtue Intelligence GmbH is responsible for the collection, pre-treatment, and proper disposal of the Level Meter.
The WEEE registration number for the Level-Meter is DE16378411. Step by step disposal process:
1. An agent will contact you.
2. The electrical waste equipment will be taken to the agreed location.
3. The manufacturer takes care of the rest.