Level Meter - Handeling Information Book

Device advantages

  1. Low Prices: Measure fill levels without putting a strain on the budget

  2. Universal Usage: It’s usable even in the deepest basement, thanks to NB-LoT module;

  3. Metering: it’s characterized by the maximum precision thanks to a infra-based method;

  4. Easy to install: For optimal transmission, the tracker should be installed outside an object with a clear view to the sky. The view must not be obstructed by metal or carbon fiber surfaces. Mounting in a closed metal enclosure can completely block radio signals, and transmitting and receiving them is no longer possible.

  5. Inside Encapsulated electronics for robust applications with a battery service life of five years on average

Level Meter Technical Specification

Communication Interface

REST, MQTT-SN

Device Size

43.48 x 85.89 x 68.00mm

Weight

<200g

IP Class

IP65

Operating Temperature

Min -20°C Max 60°C (with Chip-SIM)

Storage Temperature

Optimum 20-30°C (with Chip-SIM)

Operating Humidity

5% to 95% (non-condensing)

Storage Humidity

5% to 70% (non-condensing)

Number of SIM Slots

1x Chip-SIM

Power consumption

Quiescent current < 15uA NB-IOT Transmission < 400mA NB-IOT Receiving current < 100mA Data acquisition current < 600mA Average power consumption 0.65mAh/day Typical battery lifetime > 5 years@1.5 transmissions/day and 2 FOTA updates

ELECTRICAL SPECIFICATION

Operational Voltage

2.5- 3.0 Volt

DC

AC

Internal Battery

4800mAh@3V (Li-MnO2), 1,6g Lithium

Yes

No

CONNECTIVITY

LTE NB-IoT

Cat NB2: B1/B2/B3/B4/B5/B8/B12/B13/B17/ B18/B19/B20/B25/B28/B66/B70/B85

Antenna designed for

B8@900MHz B20@800MHz Other bands can be supported upon request

SENSOR AND IO

Accelerometer

3-Axis Accelerometer

Temperature Sensor

Integrated Temperature Sensor

Distance Sensor

Time of Flight (ToF) 5cm-160cm (Version A)

Distance Sensor

Time of Flight (ToF) 5cm-400cm (Version B)

SUPPORTED PROTOCOL LAYERS/SW FEATURES

SUPPORTED PROTOCOL

CERTIFICATES

EN301489-1 V2.2.3 EN301489-52 V1.2.1

EMC

EN301908-1/-13

Conducted RF

EN62368

Safety

EN62311

SAR

2011/65/EU

RoHS

2012/19/EU

WEEE WEEE-Reg.-Nr.: DE16378411

Other Certificates

UL1642

Only for batteries

UN38.3

Transportation

2006/66 EC 2013/56/EU

Battery Directive

EN 60068-2-5

UV resistance

IEC60086-4:2014

Safety of lithium batteries

SAFETY AND SECURITY

HOUSING MATERIAL

Housing Materials

MAC-601 UV Modified PC/ABS Alloy

Main Features

Excellent comprehensive performance Excellent weather resistance Good for paint and electro-plating Good solvent resistance Good impact performance

Level Meter Device Dimensions

Level Meter Dimentions

Level Meter TOF Types

There are two types of Level Meter equipped with different time-of-flight (TOF) sensors. The types are identified by the first serial number letter (SN prefix):

Level Meter TOF

Level Meter Device Mounting Instructions

The Level Meter must be installed in a location free from significant mechanical stresses, such as shocks, impacts, vibrations, bending, or torsional forces.

To ensure optimal cellular transmission, mount the device externally with a clear line of sight. Avoid blocking the view with metal or carbon fiber surfaces, as these can interfere with signals. Installation inside a closed metal container may fully block transmission and reception.

Mounting LM 1-2

Mounting LM 3-4

Due to the dead weight of the Level Meter, mounting using tape is not recommended.

Level Meter Installation with screws

installation LM with screws

Level Meter Installation with rivets

LM Installation with rivets

Level Meter- Device Transport Rules

Device Description for Tansport

Level Meter - Ocean freight

UN Classification

UN 3091 Lithium metal batteries in equipment, 9

Relaxation of requirement

SV 188 / SP 188 may be applicable since the batteries contain < 2g lithium.

Packaging

The batteries are protected by the device housing. As a result, there are no special requirements.

Labeling

Labeled with label UN 3091 if more than 2 packing units with 2 Level Meters units each are sent. No label is required when sending a maximum of 2 packages with 2 Level Meters units each.

Labeling for ocean freight Container

Not required

Documentation

No documentation is required.

Miscellaneous

Employees involved must be trained according to their tasks and responsibilities.

Level Meter - Road/ Rails

UN Classification

Road: UN 3091 Lithium metal batteries in equipment, 9 (E) Rail: UN 3091 Lithium metal batteries in equipment, 9

Relaxation of requirement

Exception according to 1.1.3.7 b) ADR/RID IMDG Code SP 188. SP 188 applies since the lithium content < 2 g

Packaging

The batteries are protected by the device housing. As a result, there are no special requirements.

Labeling

Labeled with label UN 3091 if more than 2 packing units with 2 Level Meters units each are sent. No label is required when sending a maximum of 2 packages with 2 Level Meters units each.

Labeling for ocean freight Container

Not required

Documentation

No documentation is required.

Miscellaneous

Employees involved must be trained according to their tasks and responsibilities.

Level Meter - PAX/CAO air freight

UN Classification

PAX/CAO air freight: UN 3091 Lithium metal batteries in equipment, 9

Relaxation of requirement

Exception according to 1.1.3.7 b) ADR/RID IMDG Code SP 188. SP 188 applies since the lithium content < 2 g

Packaging

The batteries are protected by the device housing. As a result, there are no special requirements The packaging complies with PI 970, Section II.

Labeling

Labeled with label UN 3091 if more than 2 packing units with 2 Level Meters units each are sent. No label is required when sending a maximum of 2 packages with 2 Level Meters units each.

Labeling for ocean freight Container

Not required

Documentation

No documentation is required.

Miscellaneous

The product complies with UN HANDBOOK OF TESTING AND CRITERIA - PART III, SECTION 38.3 - LITHIUM METAL AND LITHIUM ION BATTERIES. Employees involved must be trained according to their tasks and responsibilities.

Level Meter - Data and Configuration Options (Overview)

Data and Configuration Options

Level Meter- Activation Procedure

Before first use, low-cost trackers must be awakened from sleep mode to start measurements and send transmissions. Follow these steps:

LM Activation procedure steps 1-2-3
  1. Remove the cover from the lens

  2. Shake the device several times in the ToF direction.

  3. Check the LED on the back of the device.

  • If Step 2 was successfully completed, the LED on the back should light up (mode "Always On").

  • If the LED does not light up, repeat Step 2.

  1. Verify whether the registration was successful:

  • Observe the LED:

+ The LED will blink rapidly for 3 seconds and then turn off, indicating that the device has been successfully activated.

+ This process can take up to 3 minutes. After successful activation, the LED will not light up even if Step 2 is repeated.

  • Observe the LED:

+ If the LED turns off without blinking, the activation procedure has failed.

+ Possible causes:

a. An invalid network.

b. An issue with Deutsche Telekom's gIoT Cloud platform.

The installation location should be chosen so that the tracker is not exposed to strong mechanical loads, such as shock, vibration, bending and twisting forces.

Level Meter Device Functionality

The level meter regularly reports the current fill level of the container.

  • Fill level thresholds are set according to specific requirements.

  • When a threshold is reached, an alarm is triggered to ensure the container is replaced or emptied as quickly as possible.

LM Device Functionality

Level Meter - On-demand collection

Thanks to the process of optimization, the collectionis not performed at set time intervals, but the Leve Meter automatically determines the fill level

  • Optimization of container runs;

  • Reduction of manual administrative overhead;

  • Prevention of collections too early or too late.

LM OnDemand Collection

Level Meter Advantages of IoT level measurement

Sustainable

  • Process optimizations mean substantial reduction of CO2 emissions

Secure

  • Connection with the company’s NB-IoT network IoT cloud services from the certified Cloud

Efficient

  • Low costs and fixed price make for calculable costs

  • No investment required in own wireless infrastructure

  • Process optimizations mean fuel and manpower savings

Level Meter- Safety Advice

Charging the battery

The battery cannot be charged: the device includes two lithium batteries belonging to one battery package.

Improperly handling the battery can cause a fire. Do not damage or cut the device.

Use of Level Meter

Use the device only if it can be ensured that no personal injury or property damage can occur due to the installation type.

Recycling the Level Meter

As the manufacturer, Virtue Intelligence GmbH is responsible for the collection, pre-treatment, and proper disposal of the Level Meter.

The WEEE registration number for the Level-Meter is DE16378411. Step by step disposal process:

1. An agent will contact you.

2. The electrical waste equipment will be taken to the agreed location.

3. The manufacturer takes care of the rest.